Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13655731

- Product Categories
- Friendly Links
- home > Supply > Texas pressure delivery outlet | Mudanjiang pressure delivery outlet | Suntown clean air conditioning
Texas pressure delivery outlet | Mudanjiang pressure delivery outlet | Suntown clean air conditioning
Information Name: | Texas pressure delivery outlet | Mudanjiang pressure delivery outlet | Suntown clean air conditioning |
Published: | 2015-03-18 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | Leafy outlet value of positive pressure blower focus on the total amount of wind, a supervision of the secondary pressure, connecting a secondary pressure is normal, the total air volume control is not less than the minimum 650T / H, and the amount of change in value of coal, although even Do not mediate an amount of wind, air pressure once firmly linked. Positive pressure blower stall, wind, air pressure dropped significantly, leading to drastic drop positive furnace pressure outlet height, agility into four grassroots gun oil, furnace pressure to hold timely mediation firm link boiler ignition. For positive pressure blower abnormal condition quickly left the stall point. Lead someone to act as mediator structure, positive pressure blower outlet Texas, leafy exhaust port to help at least two operating pressure delivery outlet, clear division of labor. To agile splitting stall blower initiative, immediately off a small stall blower moving vane opening, so that the moving vane is less than 40%, in the blower operating state side by side, the synchronization is not quickly turn down another stalling maneuver leaf blower, running side by side so that the two air vane opening maneuver, the current phase approach, leaving the stall area after the fan, fan outlet pressure, the secondary air tank pressure rises sharply shaken furnace pressure, furnace pressure should be mediation, links furnace pressure is normal. Herein leafy outlet features: 1, leafy outlet acceptance of our ancestors to make it effective and efficient CAD program district wide; 2, the application oblique meridional flow acceleration method, the pressure is higher than the same machine axial fans, air volume compared with the same machine No big; 3, the motor built-in direct connection, small size, easy placement, stable operation; 4, low sound level than A positive outlet prices than similar products 3-5dB (A). Achieve better energy saving effect positive outlet and today we need to start from the following manufacturers have to tell you about the focus on implementing energy saving effect positive outlet knowledge, this knowledge is to know that a majority of users are more concerned in understanding this aspect After the knowledge that we can play better performance in specific applications, let's look at the specific, as follows: For this knowledge we learned positive pressure air delivery system for each floor of the building were opened outlet, object is directed to certain parts of the building, this can better prevent positive air pressure to give as gifts sufficient fresh air through the open position and the door be lost staircase, to ensure that all parts of the pressure applied uniform. In order to maintain a degree higher than the building it, they do not affect the positive effects of these smoke outlet of the staircase door open to other parts of the object can be, is permitted. The usual practice is to every 2 to 5 layers to set a positive outlet. But every other layers of competing research is to set up a blocking aspirated, blower, duct, IJ valve attached, inlet and outlet, which is yet to be confirmed. In addition, we have learned is that especially the modern high-rise building ventilation, air conditioning, plumbing criss-distributed in various parts of the building, if not handled properly, it will become a string of pipe chimney well done, therefore, must reliable fire safety measures to hedge against. In real life, each corridor must be equipped with a similar positive pressure ventilation outlet of the fire, according to fire safety requirements, according to the fire district tiering system, a system is generally not more than five, in so doing we can save duct basal area, so as to achieve the purpose of saving the building area, but can be reduced to a large two small wind turbine, saving power consumption, to achieve "energy" effect. More knowledge about the positive outlet and we will continue to bring you to organize, so stay tuned. Texas pressure delivery outlet | Mudanjiang pressure delivery outlet | Suntown clean air conditioning provided by the Texas Air Conditioning Equipment Co., Ltd. Sheng purification. Texas Air Conditioning Equipment Co., Ltd. Sheng-purification (www.dzhffj.com) strong, credible, in Dezhou fan, ventilation equipment industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead Sheng clean air conditioning and you hand in hand into the brilliant, for a better future! |
Admin>>>
You are the 26689 visitor
Copyright © GuangDong ICP No. 10089450, Texas Air Conditioning Equipment Co., Ltd. Sheng-purification All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 26689 visitor
Copyright © GuangDong ICP No. 10089450, Texas Air Conditioning Equipment Co., Ltd. Sheng-purification All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility